2. When the temperature of any special storage room in the monitored cabin reaches the set temperature of 30 ° C (preset alarm point, parameters adjustable) and 70 ° C (high-temperature alarm point, parameters adjustable), the alarm device can give alarm instructions and send light alarm signals to different special compartments.
3. The alarm device can monitor the operating signal of air conditioning in the special cabin;
4. In case of 30 ° C alarm in any special cabin, the device not only makes sound and light alarm by itself, but also immediately outputs the signal of contact without source to the special cabin air conditioning starter for starting the air conditioning;
5. When a 70 ° C warning alarm occurs in any special cabin, the device will immediately output the signal of unsourcable contacts to the ship's general alarm system, and at the same time output a set of passive contacts to the water spraying system, which is used to start the spraying system;
6. Temperature value of alarm point can be set according to demand.
It has functions of temperature display, high temperature sound and light alarm, etc.
The cabin high temperature alarm system is composed of high temperature alarm control box and flameproof temperature sensor, which can monitor the temperature of the special storage room.